Search results for "Volumetric flow rate"
showing 10 items of 116 documents
Wear and corrosion resistant performance of thermal-sprayed Fe-based amorphous coatings: A review
2019
Abstract Thermal sprayed Fe-based amorphous coatings exhibit excellent wear and corrosion resistance, and thus have been widely utilized for enhancing the performance of material surfaces. In this paper, important research progresses achieved in regards to deposition technologies and properties of thermal sprayed Fe-based amorphous coatings are reviewed. In particular, the dependence of wear and corrosion resistance of the coatings on processing parameters, e.g., kinetic energy, particle size, gas flow rate, and heat treatment temperature are summarized. Moreover, the utilization of reinforced phases and alloy elements for enhancing the wear and corrosion resistance of the coatings are pres…
Dynamic Mathematical Modelling of the Removal of Hydrophilic VOCs by Biotrickling Filters
2015
A mathematical model for the simulation of the removal of hydrophilic compounds using biotrickling filtration was developed. The model takes into account that biotrickling filters operate by using an intermittent spraying pattern. During spraying periods, a mobile liquid phase was considered, while during non-spraying periods, a stagnant liquid phase was considered. The model was calibrated and validated with data from laboratory- and industrial-scale biotrickling filters. The laboratory experiments exhibited peaks of pollutants in the outlet of the biotrickling filter during spraying periods, while during non-spraying periods, near complete removal of the pollutant was achieved. The gaseou…
Closure to “Extraction of the Flow Rate Equation under Free and Submerged Flow Conditions in Pivot Weirs with Different Side Contractions” by N. Shei…
2018
Flow Control of Fluid in Pipelines Using PID Controller
2019
In this paper, a PID controller is utilized in order to control the flow rate of the heavy oil in pipelines by controlling the vibration in a motor pump. A torsional actuator is placed on the motor pump in order to control the vibration on a motor and consequently controlling the flow rates in pipelines. The necessary conditions for the asymptotic stability of the proposed controller are validated by implementing the Lyapunov stability theorem. The theoretical concepts are validated utilizing numerical simulations and analysis, which proves the effectiveness of the PID controller in the control of flow rates in pipelines.
Humidity of Anaesthetic Gases with Respect to Low Flow Anaesthesia
1994
It has been demonstrated in an experimental study in swine using the scanning electron microscope that a rebreathing technique utilising minimal fresh gas flowrates significantly improves climatization of anaesthetic gases. Consequently, effects of various anaesthetic techniques on airway climate must be assessed, which covers the need for suitable measuring devices. Basic principles and methods of humidity measurement in flowing anaesthetic gases include gravimetric hygrometry, dew point hygrometry, wet-dry bulb psychrometry, mass spectrometry, spectroscopic hygrometry and electrical hygrometry. A custom-made apparatus for continuous measurement of humidity and temperature in the inspired…
Determination of the Herbicide Fluometuron by Photo‐induced Chemiluminescence in a Continuous‐flow Multicommutation Assembly
2007
Abstract This study was dealing with the chemiluminometric determination of the selective herbicide Fluometuron or 1,1‐dimethyl‐3‐(α,α,α‐trifluoro‐m‐tolyl)urea, (C10H11F3N2O) with a molecular weight 232.29 belongs to the phenyl urea herbicides family. The analytical strategy is based on the continuous‐flow manifold, multicommutation and the analyte pre‐treatment, the photo‐degradation. The optimization of chemical (pH, medium, temperature, and organized media) and hydrodynamic parameters (volume of reagents and flow rate) was performed by univariant and multiparametric simplex procedure respectively. Analytical figures of merit and the effect of foreign substances were studied. The method r…
Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.
2007
The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…
Reactor model for fast reactions in the micro-bubble column and validation
2007
A simple reactor model for predicting conversions in a micro-bubble column is described. It assumes fast reactions so that the gaseous component is readily consumed at the gas-liquid interface. Then, gas-liquid mass transfer becomes determining. As input parameters for the model, the hydrodynamics, specific interfacial area, and mass transport need to be described. Two fast model reactions, the catalytic oxidation of butyraldehyde and the absorption of CO2 in aqueous NaOH, show the applicability of the model but also its limits. The model was used for predicting reaction performance in dependence of operating conditions, in particular to get maximum conversion with the antagonistic paramete…
A calcined clay fixed bed adsorption studies for the removal of heavy metals from aqueous solutions
2021
Abstract A natural clay material from southern Tunisia was used as a low cost sorbent in a column-wise removal of metal pollutants. This is fundamentally important for a sustainable wastewater treatment strategy. This work has been performed within the framework of a project aiming to the valorization of natural geomaterials, from Tunisia, in several environmental applications. Column adsorption experiments were carried out for a better production of cleaner effluents and further understanding of the main mechanisms involved in the removal process, through a dynamic methodology, that would allow an industrial scale treatment. A calcined clay sample was used as an adsorbent for the removal o…
Nano-hygroscopicity tandem differential mobility analyzer (nano-HTDMA) for investigating hygroscopic properties of sub-10 nm aerosol nanoparticles
2020
Interactions between water and nanoparticles are relevant for atmospheric multiphase processes, physical chemistry, and materials science. Current knowledge of the hygroscopic and related physicochemical properties of nanoparticles, however, is restricted by the limitations of the available measurement techniques. Here, we present the design and performance of a nano-hygroscopicity tandem differential mobility analyzer (nano-HTDMA) apparatus that enables high accuracy and precision in hygroscopic growth measurements of aerosol nanoparticles with diameters less than 10 nm. Detailed methods of calibration and validation are provided. Besides maintaining accurate and stable sheath and a…